High-temperature working infrared detector Dewar heat load test technology

ZHANG Ya-ping, YANG Xiu-hua, HE Yin, HUANG Yi-bin, WANG Bo, WANG Yan, NIE Xi-liang   

  1. Kunming Institute of Physics, Kunming 650223, China
  • Received:2018-07-26 Published:2019-06-26

Abstract: Based on the development of the high temperature working infrared detector Dewar module, the conduction heat load and radiation heat load, which influences the Dewar heat load index importantly, are analyzed and the improved method of Dewar design is proposed. The conventional method of Dewar leak test and the defects of Dewar heat load test under high operating temperature are analyzed. The vacuum protection calorimetry method is adopted to realize a reliable method for heat load detection of high working temperature type Dewar components, which can promote the development of three generations of infrared focal plane detector components.

Key words: High working temperature infrared detector, Dewar, heat load, vacuum protection calorimetry method.

CLC Number: 

  • TB79
[1] Rogalski A.History of infrared detectors[J]. Opto-Electronics Review, 2012, 20(3):279-308.
[2] http://www.rigb.org/our-history/iconic-objects/iconic-objects -list/dewar-flask
[3] Breniere X, Tribolet P.IR detectors design and approach for tactical applications with high reliability without maintenance[C].Infrared Technology and Applications XXXIV. International Society for Optics and Photonics, 2008.
[4] Breiter R, Wendler J, Ziegler J.High-performance IR detector modules for Army applications[J]. Proceedings of SPIE - The International Society for Optical Engineering, 2013, 8704(1).
[5] 王小坤,张钰颖等.一种抗径向振动和冲击的冷平台支撑结构[P],201310251713, 2013,06,13.
[6] Lutz H, Breiter R, Eich D, et al.High operating temperature IR-modules with small pitch for SWaPreduction and high performance applications[C].Electro-Optical and Infrared Systems: Technology and Applications VIII. International Society for Optics and Photonics, 2011:342-349.
[7] Jain A, Banerjee A.Design, development, characterization and qualification of infrared focal plane area array detectors for space-borne imaging applications[C]. SPIE Asia-Pacific Remote Sensing. 2016:988114.
[8] Fraenkel R, Mizrahi U, Shtrichman I, et al.Cooled and uncooled infrared detectors for missile seekers[C]. Infrared Technology and Applications XL. International Society for Optics and Photonics, 2014:90700P.
[9] 田立萍, 朱颖峰, 魏东红,等. 探测器/杜瓦组件热负载自动测试系统及其应用[J]. 红外技术, 2005, 27(3):000257-259.
[10] 夏王, 王小坤, 孙闻.一种分置式杜瓦不同制冷温度下热负载测试方法及装置[P]. CN102507012. 2011,11,10.
[11] 张海燕, 管建安, 汪洋,等. 一种在线测量杜瓦冷损的数值方法[J]. 半导体光电, 2015, 36(6):909-913.
[12] 孙闻, 夏晨希, 李俊,等. 冷屏对红外探测器组件降温影响研究[J]. 激光与红外, 2017(10):1286-1289.
[13] Veprik A. Multi-slope warm-up calorimetry of Integrated Dewar-Detector Assemblies[C].Infrared Technology and Applications XLI. Infrared Technology and Applications XLI, 2015:945122-945122-10.
[1] YU Huan-qiang, ZHANG Jun-feng, DING Huai-kuang. Development of sub-cooled liquid nitrogen cooling system based on principle of decompression and cooling [J]. VACUUM, 2018, 55(6): 33-36.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] ZHOU Bin-bin, ZHANG jian, HE Jian-feng, DONG Chang-kun. Carbon nanotube field emission cathode based on direct growth technique[J]. VACUUM, 2018, 55(5): 10 -14 .
[2] LIU Yan-wen, MENG Xian-zhan, TIAN Hong, LI Fen, SHI Wen-qi, ZHU Hong, GU Bing. Test of ultra high vacuum in space traveling-wave tube[J]. VACUUM, 2018, 55(5): 25 -28 .
[3] XU Fa-jian, WANG Hai-lei, ZHAO Cai-xia, HUANG Zhi-ting. Application of chemical gases vacuum-compression recovery system in environmental engineering[J]. VACUUM, 2018, 55(5): 29 -33 .
[4] RAN Biao, LI Liu-he. The development and application of anode layer ion source[J]. VACUUM, 2018, 55(5): 51 -57 .
[5] WEI Jun、, LIU Zhi-hong, LI Bo, CHEN Xiao-li. Brazing and vacuum leak detection of large caliber alumina ceramic and stainless steel[J]. VACUUM, 2018, 55(5): 62 -65 .
[6] ZHAO Yan-hui, SHI Wen-bo, LIU Zhong-hai, LIU Zhan-qi, YU Bao-hai. Effect of deposition process parameters on arc ion plating[J]. VACUUM, 2018, 55(6): 49 -59 .
[7] Alessandro Abatecola. A new high-conductance ion pump for particle accelerator[J]. VACUUM, 2019, 56(1): 16 -19 .
[8] LUO Wei. Application and analysis of energy saving reform of condenser vacuum system[J]. VACUUM, 2018, 55(6): 37 -41 .
[9] LIU Shun-ming, SONG Hong, DONG Hai-yi, GUAN Yu-hui, LIU Sheng-hua. Applications of quadrupole mass spectrometer in drift tube linear accelerator[J]. VACUUM, 2018, 55(6): 5 -9 .
[10] GUO Chong-wu, SUN Li-chen, SUN Li-zhi, QI Fei-fei, LI Wen-bin. Mechanism research of double seal leakage in single-O-ring seal structure[J]. VACUUM, 2018, 55(6): 19 -23 .